Quantifier 93 & 94 integrating averaging sound level meters

The complete solution for industrial noise measurement and environmental noise monitoring. The Model 93 (class 1) integrating averaging sound level meters offer you all of the benefits of the affordable and easy to use Models 91 & 92, but with the addition of 1:1 Octave Band Filters.

  • Includes all the measurement functions of the Model 91 and Model 92 with the addition of 1:1 Octave Band Filters
  • 1:1 Octave Band measurements from 31Hz to 16kHz
  • Up to 12 days of 1 second Time History can be stored
  • Analyser software includes a database of PPE for the selection of appropriate hearing protection
  • Weatherproof kits available for semi-permanent outdoor monitoring
  • Calibration certificate included as standard
Buy
Service

Description

For Industrial Noise measurement these integrating averaging sound level meters offer 1:1 Octave Band Filters for the selection of accurate hearing protection. You can then choose your preferred PPE from a database of hearing defender products included in the Analyser software package.

NR and NC values and curves can also be calculated using the Analyser software.

For Environmental noise monitoring the Models 93 (Class 1) integrating-averaging sound level meters provide either an automatic or manual sweep through the filter bands in a measurement duration of as little as 1 minute for the 1:1 Octave Band Filters.

The frequency measurements are automatically time and date stamped with the 1:1 Octave Band Filters displayed as a bar graph. You can then add comments to the reports and highlight individual frequency bands.

Outdoor noise monitoring

Because environmental noise monitoring usually takes place outside, your sound level meter your Quantifier sound level meter can be supplied as part of a complete kit for taking environmental noise measurements and noise surveys. Weatherproof kits can also be provided to turn the sound level meter into a longer-term environmental noise monitoring instrument.

Features

  • Includes all the measurement functions of the Model 91 and Model 92 with the addition of 1:1 Octave Band Filters
  • 1:1 Octave Band measurements from 31Hz to 16kHz
  • Up to 12 days of 1 second Time History can be stored
  • Analyser software includes a database of PPE for the selection of appropriate hearing protection
  • Weatherproof kits available for semi-permanent outdoor monitoring
  • Calibration certificate included as standard
Accuracy

Class 1 Model 91, Model 93 & Model 95

Class 2 Model 92, Model 94 & Model 96

Applicable Standards

IEC61672-1:2002 Class 1 or 2 Group X

IEC 60651:2001 Type 1 or Type 2

IEC 60804:2000 Type 1 or Type 2

ANSI S1.4 with NK:70 Random Incidence Adaptor

1:1 & 1:3 Octave Filters to IEC 61260 Class 1 (where fitted)

Microphone (Typically)

Class 1 MK:224 pre-polarised Free-field ½ Condenser

Class 2 MK:216 pre-polarised Free-field ½ Condenser

Microphone Preamplifier

Class 1 MV:200D Removable Preamplifier

Class 2 MV:200D Integral Preamplifier

Measurement Range

Broadband 21dB(A) to 140dB(A) Class 1

25dB(A) to 140dB(A) Class 2

143dB(C) Peak (70dB to 140dB Range)

1:1 Octaves 19dB(Z) to 140dB(Z)

1:3 Octaves 14dB(Z) to 140dB(Z)

Noise Floor (Typical)

Broadband 18dB(A) Class 1, 20dB(A) Class 2

1:1 Octaves 12dB(Z) @ 1kHz 1:1 Octave Band

1:3 Octaves 7dB(Z) @ 1kHz 1:3 Octave Band

Frequency Weightings

Channel 1 ‘A’, ‘C’ or ‘Z’

Channel 2 ‘C’ for Peak

Z weighting is a flat frequency response. When either 1:1 or 1:3

Octave Band Filters are selected the ‘Z’ weighting is used.

Time Weightings

‘F’ (Fast), ‘S’ (Slow) & ‘I’ (Impulse) to IEC 61672-1:2002 Class 1 or 2 

Measurements

Broadband Mode

LAeq, LCeq or LZeq, LCpeak

LAF, LAS, LAI, LCF, LCS, LCI, LZF, LZS or LZI (not stored)

LAFmax, LASmax, LAImax, LCFmax, LCSmax, LCImax, LZFmax, LZSmax or LZImax

LAFmin, LASmin, LAImin, LCFmin, LCSmin, LCImin, LZFmin, LZSmin, LZImin

LAE, LCE or LZE, LAleq, LCleq or LZleq, LAFTeq

L0.1 to L99.9 (five simultaneous user-selected values available)

Date and time, 1 second Short Leq Noise Profile (LAeq, LCeq or LZeq)

Filter Mode

1:1 or 1:3 filter selected

Filtered LZS, LZF or LZI (not stored)

Filtered LZeq (stored), LAeq, LCeq or LZeq (stored)

Date and time

Frequency Bands (Nominal Frequencies)

1:1 Octave Band 31Hz to 16kHz

1:3 Octave Band 25Hz to 16KHz

20Hz & 20kHz 1:3 Octave band with MO:800/6 Factory Option

Memory

16Mbit memory allowing up to:

1300 broadband measurements

770 1:1 octave measurements

330 1:3 octave measurements

For example, broadband mode allows 12 days of 15 minute measurements to be stored.

Calibration records are automatically stored in the instrument memory.

Noise Profile (LAeq, LCeq or LZeq).

Short Leq (LAeq, LCeq or LZeq)

Up to 12 days at 1 second acquisition with 2 second factory set option

Automatic Measurements

The unit can be set to record and store data over fixed times of:

1 minute 5 minutes

10 minutes 15 minutes

30 minutes 1 hour

8 hours 12 hours

Display

Graphical LCD with Quasi-Analogue Display

Selected measurement parameter with level Warnings for Overload, Under Range

Battery Level & External Power Indicators

Time & Frequency Weighting

Elapsed measurement time

Real time short Leq (broadband mode)

Graphical 1:1 and 1:3 Octave Band (recall mode only)

Recalled stored measurements

Measurement Range & Instrument settings

Dimensions

340mm x 75mm x 25mm

Weight

450 gms

Batteries

2 x AA (LR6)

Battery Life

Broadband Mode typically >24 hours

Environmental

Temperature Operating –10oC to +50oC

Storage –20oC to + 60oC

Humidity Up to 95% RH Non Condensing

External Connections

USB Type B Data Out

Multipin I/O for optional connections

Outputs

Unweighted AC Output via Multipin I/O Connector

PU:90C recommended (Specify UK, EU or US plug type)

Electromagnetic Performance

IEC 61672-1:2002

IEC 61672-2:2003

Except where modified by EN 61000-6-1:2007

Output Cables

Standard: ZL:100 USB to USB

Optional: ZL812 AC Output Cable to Phono Cable

ZL:813 RS232 Output Cable

Software

Pulsar Analyser download, analysis & reporting software

Compatible with Windows 9x / Me / 2000 / NT / XP and Vista

Ordering Codes

Sound Level Meter Measurement Kit

Model 91 Model 91K

Model 92 Model 92K

Model 93 Model 93K

Model 94 Model 94K

Model 95 Model 95K

Model 96 Model 96K

Measurement Kits

Instruments can be supplied as a complete measurement kit to ensure you have all of the accessories necessary to perform your noise survey. The Quantifier noise measurement kit contains: Sound Level Meter, Acoustic Calibrator, Windshield, Hard Attache Case, Wrist Strap, Analyser Software, Download Cable, Batteries, Operating Manuals, Calibration Certificates & Extended Warranty Record.

 

Applications

  • Suitable for Industrial noise measurements and environmental noise monitoring.

The Quantifier Range.pdf

Download

Reviews

There are no reviews yet.

Be the first to review “Quantifier 93 & 94 integrating averaging sound level meters”

Your email address will not be published. Required fields are marked *